4.DESCRIPTION OF PARAMETERS B-63330EN/03
- 62 -
#7 #6 #5 #4 #3 #2 #1 #0
1092 DSP
[Input type] Parameter input
[Data type] Bitaxis
NOTE
After this parameter has been set, the power must be
off turned off then back on for the setting to become
effective.
#0 DSP Usually, do not directly enter any value, because this parameter is
specified on the FSSB setting screen. This parameter need not be
specified in the manual setting mode.
0: Two axes use a single DSP. (Ordinary axes)
1: A single axis uses a single DSP exclusively.
#7 #6 #5 #4 #3 #2 #1 #0
1093 PM2 PM1 FSL
[Input type] Parameter input
[Data type] Bitaxis
NOTE
After this parameter has been set, the power must be
off turned off then back on for the setting to become
effective.
#0 FSL The interface between the servo amplifier and the servo software is:
0: Fast type.
1: Slow type.
The servo data transfer interface is divided into two types, Fast and
Slow. The following conditions must be satisfied:
- When a 1-axis amplifier is used, either Fast or Slow type can be
used.
- When a 2-axis amplifier is used, the Fast type cannot be used for
both types.
The Slow type can be used for both axes.
- For a 3-axis amplifier, the condition for a 2-axis amplifier
applies to its first and second axes, while the condition for a 1-
axis amplifier applies to its third axis.
- The Fast type must be used for an axis for which an odd number
is set for parameter No. 1023.
The Slow type can, however, be used for EGB workpiece axes,
learning control axes, high-speed current loop axes, and high-
speed interface axes.
- Only the Slow type can be used for an axis for which an even
number is set for parameter No. 1023.
(Be sure to set this bit to 1.)