4.DESCRIPTION OF PARAMETERS B-63330EN/03
- 148 -
2072 Address value of the second I/O-Link-connected manual handle
NOTE
After this parameter has been set, the power must be
off turned off then back on for the setting to become
effective.
[Input type] Parameter input
[Data type] Integer
[Valid data range] 0 - 127
Specifies the address value (X address of the PMC) of the second I/O-
Link-connected manual handle.
NOTE
When an I/O-Link-connected manual handle is
specified for the second manual handle, but the
specified address value is not appropriate, this
parameter is automatically set to -1.
2073 Address value of the third I/O-Link-connected manual handle
NOTE
After this parameter has been set, the power must be
off turned off then back on for the setting to become
effective.
[Input type] Parameter input
[Data type] Integer
[Valid data range] 0 - 127
Specifies the address value (X address of the PMC) of the third I/O-
Link-connected manual handle.
NOTE
When an I/O-Link-connected manual handle is
specified for the third manual handle, but the
specified address value is not appropriate, this
parameter is automatically set to -1.
#7 #6 #5 #4 #3 #2 #1 #0
2080 PPE PMN SLV
[Input type] Setting input
[Data type] Bit
#0 SLV Specifies whether to use multiple-slave displays (for up to four
slaves) in the Power Mate CNC manager function, as follows:
0: Do not use.
1: Use.