B-63330EN/03 4.DESCRIPTION OF PARAMETERS
- 223 -
5561
Compensation corresponding to compensation point number a of move axis 2
5562
Compensation corresponding to compensation point number b of move axis 2
5563
Compensation corresponding to compensation point number c of move axis 2
5564
Compensation corresponding to compensation point number d of move axis 2
NOTE
After this parameter has been set, the power must be
off turned off then back on for the setting to become
effective.
[Input type] Parameter input
[Data type] Integer
[Unit of data] detection unit
[Valid data range] -32767 - 32767
Note) Set a compensation for each compensation point.
5571
Compensation corresponding to compensation point number a of move axis 3
5572
Compensation corresponding to compensation point number b of move axis 3
5573
Compensation corresponding to compensation point number c of move axis 3
5574
Compensation corresponding to compensation point number d of move axis 3
NOTE
After this parameter has been set, the power must be
off turned off then back on for the setting to become
effective.
[Input type] Parameter input
[Data type] Integer
[Unit of data] detection unit
[Valid data range] -32767 - 32767
Note) Set a compensation for each compensation point.