B-63330EN/03 4.DESCRIPTION OF PARAMETERS
- 159 -
#7 ODR Specifies the units of the program sizes on the program directory
screen.
0: KB units.
1: Page units. (The page refers to the management unit within the
CNC.)
#7 #6 #5 #4 #3 #2 #1 #0
2219 MLC TPC
[Input type] Parameter input
[Data type] Bit
#0 TPC Specifies whether to display the touch panel compensation screen.
0: Not displayed.
1: Displayed.
Usually, set this bit to 0. Touch panel compensation is required only
when a new panel is installed, when the existing panel is replaced, or
when memory is all cleared. Set the bit to 1 only when touch panel
compensation is to be performed. After the end of compensation, set it
to 0.
#3 MLC At power on, the 2-LCD-unit connection function selects:
0: the LCD unit specified for parameter No.2221.
1: the LCD unit selected before the power was disconnected.
2221 Number of the LCD unit to be selected at power on
[Input type] Parameter input
[Data type] Integer
[Valid data range] 0 and 1
Enter the number of the first LCD unit to be selected at power on
using the 2-LCD-unit connection function.
Entering 0 causes LCD unit 1 to be selected. Entering 1 causes LCD
unit 2 to be selected.
If a number larger than the number of mounted LCD units is entered,
the last LCD unit will be selected.
2231 Axis number on the load meter for the first servo axis
2232 Axis number on the load meter for the second servo axis
2233 Axis number on the load meter for the third servo axis
[Input type] Parameter input
[Data type] Integer
[Valid data range] 0 - Max axes
Specify the axis number to be displayed on the load meter for the
servo axis.