4.DESCRIPTION OF PARAMETERS B-63330EN/03
- 186 -
4637 Vertical axis graduation unit 4
[Input type] Parameter input
[Data type] Integer
[Valid data range] 1 - 500000
Specify the value equivalent to one graduation on the horizontal axis
of trace data item 4.
4638 Waveform color 3
[Input type] Parameter input
[Data type] Integer
[Valid data range] 0 - 7
Specify the drawing color of trace data item 3.
0: White 1: Red 2: Green 3: Yellow
4: Blue 5: Violet 6: Light blue 7: White
4639 Waveform color 4
[Input type] Parameter input
[Data type] Integer
[Valid data range] 0 - 7
Specify the drawing color of trace data item 4.
0: White 1: Red 2: Green 3: Yellow
4: Blue 5: Violet 6: Light blue 7: White
#7 #6 #5 #4 #3 #2 #1 #0
4660 ATL SPL TQ2 TQ1
[Input type] Parameter input
[Data type] Bit
#0, #1 TQ1 TQ2
Set a store interval for the fine torque sensing function.
Store interval TQ2 TQ1
8ms 0 0
16ms 0 1
32ms 1 0
#2 SPL The function for saving stored disturbance load torque data as sample
data is:
0: Disabled.
1: Enabled.
#4 ATL On the fine torque sensing graph screen, a modification to the
abnormal load detection alarm threshold value is:
0: Impossible.
1: Possible.
When this bit is set to 1, a modification to the abnormal load
detection alarm threshold value can be made on the fine torque