B-63330EN/03 4.DESCRIPTION OF PARAMETERS
- 69 -
4.8 COORDINATE SYSTEM PARAMETERS (DATA NO. 1200
AND LATER)
#7 #6 #5 #4 #3 #2 #1 #0
1200 ACP NZA DSC MNS FPC
[Input type] Parameter input
[Data type] Bit
#1 FPC Specifies whether to preset the relative position display to zero when
the floating reference position is set using the appropriate soft key.
0: Do not set to 0 (relative position display remains unchanged) .
1: Set to 0.
#2 MNS Specifies whether to shift coordinate systems when data is written
into the system variables which specifies the distance to be caused by
a manual interrupt.
0: Shift all workpiece coordinate systems and local coordinate
systems.
1: Do not shift any workpiece coordinate system or local coordinate
system. (This is the same operation as that specified by the
"cancel" soft key on the manual-interrupt-distance screen.)
#5 DSC Specifies the type of coordinates to be read when the skip signal
position is read using custom macro system variables #5061 to #5080
(ABSKP) in three-dimensional coordinate conversion mode.
0: Coordinates in the coordinate system for which coordinate
conversion is not performed (workpiece coordinate system)
1: Coordinates in the coordinate system for which coordinate
conversion has been performed (program coordinate system)
NOTE
When the skip signal position is read in a mode other
than three-dimensional coordinate conversion mode
(G69 mode), coordinates in the coordinate system for
which coordinate conversion is not performed
(workpiece coordinate system) are read.
For an explanation of system variables #5041 to
#5060 (ABSOT), see the explanation of D3M (bit 5 of
parameter No. 6400).
#6 NZA Specifies whether to issue the PS181 alarm if the machine is in the
lock state when the reference position return function is enabled, and
a move command is specified for an axis along which the reference
position return is not completed.
0: Issue the alarm.
1: Do not issue the alarm.
#7 ACP Specifies whether to perform the automatic workpiece coordinate
system preset when the machine lock signal switches from on to off in
the preset state.
0: Do not perform the preset.
1: Perform the preset.