B-63330EN/03 4.DESCRIPTION OF PARAMETERS
- 163 -
parameters are set to 0, the function is ignored, and the whole
program is drawn. Normally, specify 0.
NOTE
Blocks Oxxxxxxxx and Nxxxxxxxx, which correspond
respectively to the program and sequence numbers to
be specified in the above parameters, must be single
blocks or contain NC statements. If a subprogram,
macro program, or command for calling a macro
program is specified for the block, the block is
ignored.
2278 Background drawing program number
[Input type] Parameter input
[Data type] Integer
[Valid data range] 0 - 99999999
Specify the number of the desired drawing program. Press the HEAD
soft key to move the drawing program pointer to the head of the
program number specified by this parameter.
#7 #6 #5 #4 #3 #2 #1 #0
2286 NDP JIS PDS MDC JSP
[Input type] Parameter input
[Data type] Bit
#1 JSP Display the following on the overall position display screen or the
program check screen.
In manual operation mode:
Jog feed rate (X-axis) with any override included.
Automatic operation mode:
Dry run speed with any override included.
0: Does not display the jog feed rate or dry run speed.
1: Displays the jog feed rate or dry run speed.
#3 MDC Specifies whether to allow erasing of all maintenance information.
0: Not allowed.
1: Allowed.
#5 PDS Specifies whether to display the status when a life warning is issued
for data registered on the periodic maintenance screen.
0: Not displayed.
1: Displayed.