4.DESCRIPTION OF PARAMETERS B-63330EN/03
- 40 -
4.5 Timer Parameters (Data No. 0100 and later)
0100 Time accumulated since power-on
[Input type] Parameter input
[Data type] Integer
[Unit of data] min
[Valid data range] 0 - 999999999
Stores the time accumulated since power-on.
0101 Time 1 accumulated during automatic operation
[Input type] Setting input
[Data type] Integer
[Unit of data] msec
[Valid data range] 0 - 59999
Stores the time accumulated during automatic operation that is less
than one minute. The actual time accumulated during automatic
operation is the sum of this parameter and parameter No. 102.
0102 Time 2 accumulated during automatic operation
[Input type] Setting input
[Data type] Integer
[Unit of data] min
[Valid data range] 0 - 999999999
Stores the time accumulated during automatic operation that is equal
to or greater than one minute. The actual time accumulated during
automatic operation is the sum of this parameter and parameter No.
101.
0103 Time 1 accumulated during cutting
[Input type] Setting input
[Data type] Integer
[Unit of data] msec
[Valid data range] 0 - 59999
Stores the time accumulated during cutting that is less than one
minute. The actual time accumulated during cutting is the sum of this
parameter and parameter No. 104.