B-63330EN/03 4.DESCRIPTION OF PARAMETERS
- 81 -
1413 Maximum number of buffered manual handle feed pulses
[Input type] Parameter input
[Data type] Integer
[Valid data range] 0 - 4
The permissible flow amount is set. If such a handle feed that
momentarily exceeds the rapid traverse rate is specified, the handle
pulses for the excess of the rapid traverse rate are not discarded, but
are accumulated according to the setting.
)setting(
)rate traverserapid(
amount flow ePermissibl
×
=
Normally, 0 may be set.
1414 Magnification m of manual handle feed
[Input type] Parameter input
[Data type] Integer
[Valid data range] 0 - 2000
Set the magnification m for when movement selection signals MP1
and MP2 for manual handle feed are 0 and 1, respectively.
Travel amount select signal
MP4 MP2 MP1
Amount of travel
(manual handle feed)
0 0 0 Least input increment × 1
0 0 1 Least input increment × 10
010
Least input increment × m
1
011
Least input increment × n
2
*1 To be set in parameter No.1414.
*2 To be set in parameter No.1418.
1417 Rapid traverse ratio during the period from the power on to manual
reference position return
[Input type] Parameter input
[Data type] Integer
[Unit of data] %
[Valid data range] 0 - 100
Set the rapid traverse ratio to use in the below expression. This
expression is used to calculate the effective rapid traverse feedrate
during the power on to manual reference position return.
(rapid traverse feedrate) = (feedrate set in parameter No. 1420) x
(value set in this parameter) /100
When 0 is set, the feedrate is assumed to be 100%.