B-63330EN/03 4.DESCRIPTION OF PARAMETERS
- 199 -
5073 RS-422 baud rate (remote buffer)
[Input type] Setting input
[Data type] Integer
[Valid data range] 2 – 15
Specify the RS422 device baud rate of the remote buffer.
The valid settings are given below, together with the corresponding
baud rates.
1 : 50, 2 : 100, 3 : 110, 4 : 150, 5 : 200, 6 : 300, 7 : 600. 8 : 1200,
9 : 2400, 10 : 4800, 11 : 9600, 12 : 19200, 13 : 38400, 14 : 76800,
15 : 86400 [bps]
5074 RS-422 protocol selection (remote buffer)
NOTE
After this parameter has been set, the power must
be off turned off then back on for the setting to
become effective.
[Input type] Setting input
[Data type] Integer
[Valid data range] 1 - 3
1: Protocol B
2: Extended protocol B
3: Protocol A/extended protocol A
Switching between protocol A and extended protocol A is performed
with the appropriate parameter of the <SET> command.
For details of each protocol, refer to the supplementary manual
supplied with the remote buffer.
NOTE
If protocol A/extended protocol A is selected, any
changes to the following parameters take effect
after the power is turned OFF and then ON again:
Nos. 5070, 5072, and 5073
5081 RS-232-C I/O device type number (remote buffer)
[Input type] Setting input
[Data type] Integer
[Valid data range] 0,7,8
Set the type number of the RS-232-C I/O device host of the remote
buffer.
7: FANUC Cassette, PROGRAM FILE
8: PROGRAM FILE Mate, Floppy Cassette
0: Type other than the above
For example, if using a personal computer, set 0.