4.DESCRIPTION OF PARAMETERS B-63330EN/03
- 350 -
7632 M code used to specify the negative-direction rotation of an index table
indexing axis
[Input type] Parameter input
[Data type] Integer
[Valid data range] 0 - 127
0: The rotation direction of an index table indexing axis is determined
by the setting of the parameter (7602#4 INC) and command.
1 to 127: The rotation direction of an index table indexing axis is
always positive. The rotation direction is negative only when a move
command is specified together with the M code set.
7633 M code for turning off synchronization in synchronous control and twin table
control
[Input type] Parameter input
[Data type] Integer
[Valid data range] 1 - 999999999
Specify an M code for switching from synchronous operation to
independent operation or normal operation.
The M code set in this parameter is not buffered.
7634 M code for turning on synchronization in synchronous control and twin table
control
[Input type] Parameter input
[Data type] Integer
[Valid data range] 1 - 999999999
Specify the M code that causes switching from independent or normal
operation to synchronous operation.
The M code specified for this parameter is treated as an M code
without buffering.
7635 Number of axes in a single block that can accept commands (remote buffer)
[Input type] Parameter input
[Data type] Integer
[Valid data range] 0 - Max axes
Set the number of axes in a single block that can accept commands
when using binary input operation mode. Do not change this
parameter during operation.
NOTE
The axes that can accept commands from the
remote buffer are the first n axes in the controlled
axis list, where n is the number of axes specified for
this parameter.
For example, when this parameter is 3, the fourth
and any subsequent axes in the controlled axis list
cannot accept commands.