B-63330EN/03 4.DESCRIPTION OF PARAMETERS
- 85 -
1451 F1 feedrate
1452 F2 feedrate
1453 F3 feedrate
1454 F4 feedrate
1455 F5 feedrate
1456 F6 feedrate
1457 F7 feedrate
1458 F8 feedrate
1459 F9 feedrate
[Input type] Setting input
[Data type] Real
[Unit of data] mm/min, inch/min, degree/min (machine unit)
[Minimum unit of data] Depend on the increment system of the reference axis
[Valid data range] Refer to the standard parameter setting table (C)
(When the increment system is IS-B, 0.0 - +240000.0)
Specify the feedrate assigned to the F code with a one-digit number
Fn (n=1 to 9) . When the feedrate is changed by the manual pulse
generator, this parameter changes along with the change in the
feedrate.
1460 Upper feedrate limit for F1 to F4
[Input type] Parameter input
[Data type] Real
[Unit of data] mm/min, inch/min, degree/min (machine unit)
[Minimum unit of data] Depend on the increment system of the reference axis
[Valid data range] Refer to the standard parameter setting table (C)
(When the increment system is IS-B, 0.0 - +240000.0)
Set the upper limits for the feedrates specified by the F codes with a
one-digit number. When the feedrate is increased by turning the
manual pulse generator, these upper limits are used to clamp the
feedrate. The upper limit of feedrates for F1 to F4 is specified in this
parameter.