B-63330EN/03 4.DESCRIPTION OF PARAMETERS
- 351 -
7636 Number of a linear axis for which exponential interpolation is performed
[Input type] Parameter input
[Data type] Integer
[Valid data range] 1 - Max axes
Set the ordinal controlled axis number of a linear axis for which
exponential interpolation is performed.
7637 Number of a rotation axis for which exponential interpolation is performed
[Input type] Parameter input
[Data type] Integer
[Valid data range] 1 - Max axes
Set the ordinal controlled axis number of a rotation axis for which
exponential interpolation is performed.
7642 M code that causes switching to independent operation during twin table
control
Specify the M code that causes switching from synchronous or normal
operation to independent operation.
The M code specified for this parameter is handled as an M code
without buffering.
7651 Interference allowance when the block is restarted (d)
[Input type] Setting input
[Data type] Real
[Unit of data] mm, inch (input unit)
[Minimum unit of data] Depend on the increment system of the applied axis
[Valid data range] 9 digit of minimum unit of data (refer to standard parameter setting
table (A) ) (When the increment system is IS-B, -999999.999 -
+999999.999)
Set an allowable distance between the normal path after cutter
compensation and the block restart position.
If the distance between the normal path and restart position is equal to
or greater than d, a warning about interference is issued to protect
against overcutting.
7672 Maximum travel of a block executed with smooth interpolation
[Input type] Setting input
[Data type] Real
[Unit of data] mm, inch (input unit)
[Minimum unit of data] Depend on the increment system of the reference axis
[Valid data range] 9 digit of minimum unit of data (refer to standard parameter setting
table (A) )
(When the increment system is IS-B, -999999.999 - +999999.999)