B-63330EN/03 4.DESCRIPTION OF PARAMETERS
- 221 -
5501 Compensation point number a of straightness compensation move axis 1
5502 Compensation point number b of straightness compensation move axis 1
5503 Compensation point number c of straightness compensation move axis 1
5504 Compensation point number d of straightness compensation move axis 1
NOTE
After this parameter has been set, the power must be
off turned off then back on for the setting to become
effective.
[Input type] Parameter input
[Data type] Integer
[Unit of data] detection unit
[Valid data range] From 0 through 1279 or from 0 through 3071 depending on the
number of controlled axes is less than or equal to 10 or greater than
10, respectively.
Set a compensation point number in stored pitch error compensation.
Fourth among the four compensation points set for each move axis.
5511 Compensation point number a of straightness compensation move axis 2
5512 Compensation point number b of straightness compensation move axis 2
5513 Compensation point number c of straightness compensation move axis 2
5514 Compensation point number d of straightness compensation move axis 2
NOTE
After this parameter has been set, the power must be
off turned off then back on for the setting to become
effective.
[Input type] Parameter input
[Data type] Integer
[Valid data range] From 0 through 1279 or from 0 through 3071 depending on the
number of controlled axes is less than or equal to 10 or greater than
10, respectively.
Set a compensation point number in stored pitch error compensation.