B-63330EN/03 4.DESCRIPTION OF PARAMETERS
- 237 -
#7 #6 #5 #4 #3 #2 #1 #0
5807 ALM
[Input type] Parameter input
[Data type] Bit
#0 ALM Specifies whether the spindle alarms (SPxxxx) of all spindles are
enabled or ignored.
0: Enabled.
1: Ignored.
When this parameter is set to 1, the spindle-related alarms are ignored.
So, set this parameter to 0 at all times except in maintenance.
#7 #6 #5 #4 #3 #2 #1 #0
5808 FLR OMI
[Input type] Parameter input
[Data type] Bitspindle
#0 OMI Specifies whether the spindle positioning orientation direction is the
plus direction or minus direction when an analog spindle is used.
0: Plus direction
1: Minus direction
#1 FLR Specifies the measurement unit for the permission ratio (q) and
fluctuation ratio (r) specified in spindle speed fluctuation detection
parameter Nos. 5701 and 5702, respectively, as follows:
0: 1% units
1: 0.1% units
#7 #6 #5 #4 #3 #2 #1 #0
5809 IOE AIT
[Input type] Parameter input
[Data type] Bitspindle
#0 AIT Specifies whether to enable or disable axis-by-axis interlock for a
spindle positioning axis.
0: Disable.
1: Enable.
#1 IOE Specifies whether to cancel the spindle positioning mode upon
emergency stop.
0: Do not cancel.
1: Cancel.