4.DESCRIPTION OF PARAMETERS B-63330EN/03
- 42 -
0109 Number of parts required
[Input type] Setting input
[Data type] Integer
[Valid data range] 0 - 999999999
Sets the number of parts required. When the total number of
machined parts exceeds the value of this parameter, a signal
indicating that the number of parts required is exceeded is output.
0130 Time by which to go back to delete alarms from the history
[Input type] Parameter input
[Data type] Integer
[Unit of data] sec
[Valid data range] 0 - 255
When the power to the NC is turned ON, the NC goes back from the
time the NC was turned OFF by the specified time and deletes from
the history any alarms that occurred during this period.
If this parameter is set to 0, one second is assumed.