4.DESCRIPTION OF PARAMETERS B-63330EN/03
- 324 -
7220 Time width from input of a skip signal until the input of the next skip signal
is enabled when the EGB skip function is used
[Input type] Parameter input
[Data type] Integer
[Unit of data] 8msec
[Valid data range] From 3 through 127. Other values are taken as 3.
Set the time width from input of a skip signal until the input of the
next skip signal is enabled (becomes acceptable) when the EGB skip
function is used.
Set a value in steps of 8 msec.
Example: When 10 is set, 80 msec is assumed.
This parameter is set to prevent the system from accepting a skip
signal mistakenly.
Parameter-set time
Skip signal <1>
<2>
<3>
After skip signal <1>, skip signal <2> is ignored because it is input
within the parameter-set time. Skip signal <3> is valid.
#7 #6 #5 #4 #3 #2 #1 #0
7300 SEB AMH MDC
[Input type] Parameter input
[Data type] Bit
#0 MDC Specifies whether the result of an automatic tool length measurement
is subtracted from or added to the current offset value.
0: Subtracted.
1: Added.
NOTE
The standard setting is 1.
#1 AMH Specifies whether to use the high-speed measurement position arrival
signal for automatic tool length measurement.
0: Do not use. Instead, the conventional measurement position
arrival signal is used.
1: Use.