4.DESCRIPTION OF PARAMETERS B-63330EN/03
- 80 -
#7 JFM This sets the command increment of feedrate data in the continuous
feed command (16H) during PMC axis control.
0: The unit of feedrate data depends on the setting of parameter
F10 (bit 1 of parameter No. 1409) .
1:
Unit of data
IS-A IS-B IS-C IS-D IS-E
unit
Metric input
2000.0 200.0 20.0 2.0 0.2 mm/min
Linear
axis
Inch input
200.0 20.0 2.0 0.2 0.02 inch/min
Rotary axis
2000.0 200.0 20.0 2.0 0.2 deg/min
NOTE
If this parameter is set to 1, parameter F10 (bit 1 of
parameter No. 1409) must also be set to 1.
1410 Dry run feedrate
[Input type] Parameter input
[Data type] Real
[Unit of data] mm/min, inch/min, degree/min (machine unit)
[Minimum unit of data] Depend on the increment system of the reference axis
[Valid data range] Refer to the standard parameter setting table (C)
(When the increment system is IS-B, 0.0 - +240000.0)
Set the dry run feedrate for when the jog feedrate dial is turned to
100%. The unit of data depends on the increment system of the basic
axes.
1411 Arbitrary manual angle feedrate
[Input type] Parameter input
[Data type] Real
[Unit of data] mm/min, inch/min (machine unit)
[Minimum unit of data] Depend on the increment system of the reference axis
[Valid data range] Refer to the standard parameter setting table (C)
(When the increment system is IS-B, 0.0 - +240000.0)
Set the arbitrary manual angle feedrate for when the jogging feedrate
dial is turned to 100%. The unit of data depends on the increment
system of the basic axes.
1412 Percentage value for rapid traverse override F1
[Input type] Parameter input
[Data type] Integer
[Unit of data] %
[Valid data range] 0 - 100
Set the percentage value to use for rapid traverse override F1.