2.SETTING PARAMETERS AND PITCH ERROR COMPENSATION DATA B-63330EN/03
- 10 -
2.2 SETTING PITCH ERROR COMPENSATION DATA
For an explanation of how to display the Pitch Error Compensation
screen, see Section 1.2, "Displaying Pitch Error Compensation Data."
The Pitch Error Compensation screen is used to set pitch error
compensation data.
Procedure for setting pitch error compensation data
- Entering the mode
Enter MDI mode. Alternatively, press the emergency stop button to
enter the emergency stop status.
- Setting parameter PWE
On the Setting Parameter screen, set bit 0 of the setting/input-enabled
parameter PWE (No. 8000) to 1.
For the setting procedure, refer to Section II-9.3, "Displaying and
Setting Setting Parameters" in the "FANUC Series 15i/150i-MA
OPERATOR’S MANUAL (Operation)."
- Moving the cursor
Move the cursor to the pitch error compensation data to be set.
Method 1
Using the <PAGE ↑> <PAGE ↓> page keys, and the <↑> <↓>
<←> <→> cursor keys, to move the cursor.
Method 2
(1) Click the [NO. SEARCH] soft key.
(2) Key in the pitch error compensation data number.
(3) Click the [EXEC] soft key.
Method 3
(1) Key in the pitch error compensation data number.
(2) Click the [NO. SEARCH] soft key.
- Entering a setting (absolute input)
Method 1
(1) Click the [INPUT] soft key.
(2) Key in the desired setting.
(3) Click the [EXEC] soft key.
Method 2
(1) Key in the desired setting.
(2) Click the [INPUT] soft key. B
Method 3
(1) Key in the desired setting.
(2) Click the [INPUT] soft key.
B