B-63330EN/03 4.DESCRIPTION OF PARAMETERS
- 139 -
#1 SSN Specifies whether a minus (-) can be used in an S code.
0: Cannot be used
1: Can be used
NOTE
To enable the use of a minus (-) in an S code, the
allowable number of digits in an S code must be nine
or less.
#2 TSN Specifies whether a minus (-) can be used in a T code.
0: Cannot be used
1: Can be used
NOTE
To enable the use of a minus (-) in a T code, the
allowable number of digits in an T code must be nine
or less.
#3 BSN Specifies whether a minus (-) can be used in the specification of the
2nd auxiliary function.
0: Cannot be used
1: Can be used
NOTE
To enable the use of a minus (-) in the 2nd auxiliary
function, the allowable number of digits in the 2nd
auxiliary function must be nine or less.
#7 #6 #5 #4 #3 #2 #1 #0
2004 MHI
[Input type] Parameter input
[Data type] Bit
#0 MHI The strobe and completion signals for the M, S, T, or B codes are
transmitted in the:
0: Normal system.
1: High-speed system.
#7 #6 #5 #4 #3 #2 #1 #0
2005 SKE D3A PDT DIT
[Input type] Parameter input
[Data type] Bit
#1 DIT Specifies whether to enable the all-axis/axis-by-axis interlock
function for the axes controlled by PMC axis control.
0: Enable the all-axis/axis-by-axis interlock function along axes
under PMC control.
1: Disable the all-axis-axis-by-axis interlock function along axes
under PMC control. (Movements along the axes are not
stopped.)