B-63330EN/03 4.DESCRIPTION OF PARAMETERS
- 217 -
Set the interval between second cyclical pitch error compensation
points for each axis.
5433 Magnification for second cyclical pitch error compensation for each axis
NOTE
After this parameter has been set, the power must be
off turned off then back on for the setting to become
effective.
[Input type] Parameter input
[Data type] Integeraxis
[Valid data range] 0 - 100
Set a magnification for second cyclical pitch error compensation for
each axis.
When 1 is set as the magnification for second cyclical pitch error
compensation, the unit of compensation data is the same as the
detection unit.
5440 Axis for which three-dimensional error compensation is performed (1st axis)
5441 Axis for which three-dimensional error compensation is performed (2nd axis)
5442 Axis for which three-dimensional error compensation is performed (3rd axis)
NOTE
After this parameter has been set, the power must be
off turned off then back on for the setting to become
effective.
[Input type] Parameter input
[Data type] Integer
[Valid data range] 1 - Max axes
Set three axes for which three-dimensional error compensation is
performed.
5443 Number of three-dimensional error compensation points (1-st axis)
5444 Number of three-dimensional error compensation points (2-nd axis)
5445 Number of three-dimensional error compensation points (3-rd axis)
[Input type] Parameter input
[Data type] Integer
[Valid data range] 2 - 25
Set the number of three-dimensional error compensation points.