B-63330EN/03 4.DESCRIPTION OF PARAMETERS
- 35 -
#7 #6 #5 #4 #3 #2 #1 #0
0015 NDM EKE OHS HPC SPS SVS
[Input type] Setting input
[Data type] Bit
#0 SVS Specifies whether to display the servo screen.
0: Display the servo screen.
1: Do not display the servo screen.
Specifies whether to display or hide the servo setting screen, servo
adjustment/monitor screen, servo function setting screen, servo alarm
screen, and backlash screen.
#1 SPS Specifies whether to display the spindle screen.
0: Display the spindle screen.
1: Do not display the spindle screen.
#2 HPC Specifies whether to enable the high-speed and high-precision
machining setting screen.
0: Enable the screen.
1: Disable the screen.
#3 OHS Specifies whether to display the operation history screen and the
signal selection screen.
0: Do not display the screens. (The alarm history screen can be
displayed.)
1: Display the screens.
#4 EKE Specifies whether to enable the [ALL CLEAR] soft key that erases
history data.
0: Disable the soft key.
1: Enable the soft key.
#7 NDM
The PROFIBUS-DP screen is
0: Displayed.
1: Not displayed.
The change of this bit takes effect at the next startup.
0016 Screen saver start time
[Input type] Setting input
[Data type] Integer
[Unit of data] min
[Valid data range] 0 - 127
When the operator does not operate the keyboard for the period
specified in this parameter, the saver screen is displayed. When 0 is
specified, the screen save function is disabled.
0020 Interface No. of input device for foreground
[Input type] Setting input
[Data type] Integer
[Valid data range] 0 - 21
This parameter specifies an interface number for a foreground input
device.