B-63330EN/03 4.DESCRIPTION OF PARAMETERS
- 305 -
#2 DSM Specifies whether a system variable that can be specified (written) on
the let side can be rewritten on the custom macro screen through the
MDI unit.
0: Cannot be rewritten.
1: Can be rewritten.
#7 #6 #5 #4 #3 #2 #1 #0
7004 ISO
[Input type] Parameter input
[Data type] Bit
#1 ISO
0: When EIA codes are used, set in parameter No. 7010 through No.
7018 the bit patterns of codes specified instead of [, ], #, *, =, ?,
@, &, and _.
1: When ISO/ASCII codes are used, set in parameter No. 7010
through No. 7018 the bit patterns of codes specified instead of
[, ], #, *, =, ?, @, &, and _.
#7 #6 #5 #4 #3 #2 #1 #0
7010 [7 [6 [5 [4 [3 [2 [1 [0
7011 ]7 ]6 ]5 ]4 ]3 ]2 ]1 ]0
7012 #7 #6
#4 #3 #2 #1 #0
7013 *7 *6 *5 *4 *3 *2 *1 *0
7014 =7 =6
=4 =3 =2 =1 =0
7015 ?7 ?6
?4 ?3 ?2 ?1 ?0
7016 @7 @6
@4 @3 @2 @1 @0
7017 &7 &6
&4 &3 &2 &1 &0
7018 _7 _6
_4 _3 _2 _1 _0
[Input type] Parameter input
[Data type] Bit
[0 to [7 : The bit pattern of the EIA or ISO/ASCII code indicating [ is set.
]0 to ]7 : The bit pattern of the EIA or ISO/ASCII code indicating ] is set.
#0 to #7 : The bit pattern of the EIA or ISO/ASCII code indicating # is set.
*0 to *7 : The bit pattern of the EIA or ISO/ASCII code indicating * is set.
=0 to =7 : The bit pattern of the EIA or ISO/ASCII code indicating = is set.
?0 to ?7 : The bit pattern of the EIA or ISO/ASCII code indicating ? is set.
@0 to @7 : The bit pattern of the EIA or ISO/ASCII code indicating @ is set.
&0 to &7 : The bit pattern of the EIA or ISO/ASCII code indicating & is set.
_0 to _7 : The bit pattern of the EIA or ISO/ASCII code indicating _ is set.
0: A corresponding bit is 0.
1: A corresponding bit is 1.