4.DESCRIPTION OF PARAMETERS B-63330EN/03
- 92 -
1522 Post-interpolation acceleration/deceleration time constant (for finishing)
[Input type] Parameter input
[Data type] Integeraxis
[Unit of data] msec
[Valid data range] 0 - 4000
Stores the post-interpolation acceleration/deceleration time constant
for the finishing parameter set. Usually, the time constant is entered
from the HPCC (SETTING) screen. If a different value needs to be
set for an axis, this parameter must be directly specified. To make the
setting effective during operation, the "SELECT ACTIVE" key must
be pressed on the HPCC (SETTING) screen.
1524 Corner feedrate difference (for finishing)
[Input type] Parameter input
[Data type] Realaxis
[Unit of data] mm/min, inch/min, degree/min (machine unit)
[Minimum unit of data] Depend on the increment system of the applied axis
[Valid data range] Refer to the standard parameter setting table (C)
(When the increment system is IS-B, 0.0 - +240000.0)
Stores the corner feedrate difference for the finishing parameter set.
Usually, the difference is entered from the HPCC (SETTING) screen.
If a different value needs to be set for an axis, this parameter must be
directly specified. To make the setting effective during operation, the
"SELECT ACTIVE" key must be pressed on the HPCC (SETTING)
screen.
1529 Feed-forward factor (for finishing)
[Input type] Parameter input
[Data type] Integeraxis
[Valid data range] 0 - 10000
Stores the feed-forward factor for the finishing parameter set. Usually,
the factor is entered from the HPCC (SETTING) screen. If a different
value needs to be set for an axis, this parameter must be directly
specified. To make the setting effective during operation, the
"SELECT ACTIVE" key must be pressed on the HPCC (SETTING)
screen.
1533 Acceleration level (for finishing)
[Input type] Parameter input
[Data type] Integer
[Unit of data] %
[Valid data range] 0 - 200
Stores the acceleration level for the finishing parameter set. Usually,
the level is entered from the HPCC (SETTING) screen and, therefore,
this parameter need not be directly specified.