4.DESCRIPTION OF PARAMETERS B-63330EN/03
- 208 -
5270 Controlled axis for which the 1-st position switch function is performed
(PSWA01)
5271 Controlled axis for which the 2-nd position switch function is performed
(PSWA02)
5272 Controlled axis for which the 3-rd position switch function is performed
(PSWA03)
5273 Controlled axis for which the 4-th position switch function is performed
(PSWA04)
5274 Controlled axis for which the 5-th position switch function is performed
(PSWA05)
5275 Controlled axis for which the 6-th position switch function is performed
(PSWA06)
5276 Controlled axis for which the 7-th position switch function is performed
(PSWA07)
5277 Controlled axis for which the 8-th position switch function is performed
(PSWA08)
5278 Controlled axis for which the 9-th position switch function is performed
(PSWA09)
5279 Controlled axis for which the 10-th position switch function is performed
(PSWA10)
[Input type] Parameter input
[Data type] Integer
[Valid data range] 0 - Max axes
Set the controlled axis number corresponding to one of the first to
tenth position switch functions. When the machine coordinate of the
corresponding axis is within a parameter-set range, the corresponding
position switch signal is output to the PMC. The position switch
signal corresponding to the n-th position switch function is PSWn (n:
1 to 10) .
NOTE
The setting of 0 means that the position switch
function of the number is not used.