4.DESCRIPTION OF PARAMETERS B-63330EN/03
- 160 -
2234 Rated load to be displayed on the load meter of the 1st analog spindle motor
[Input type] Parameter input
[Data type] Integer
[Valid data range] From 0 through 128
Specify the rated load of the motor corresponding to the load meter.
Example) When the load meter is at 100% and the input to the AD
converter is 6 [V],
Set 128 x 6 [V]/10 [V] = 77.
2238 Program check screen position display type
[Input type] Setting input
[Data type] Integer
[Valid data range] 0 - 2
Specify the type of the current position display on the program check
screen.
Setting Position display type
0 Relative position display
1 Absolute position display
2 Machine position display
The current position display type can be changed using the
appropriate soft key on the program check screen. When the type is
changed using the soft key, this parameter is automatically changed.
2239 Percentage at which a life warning is displayed on the periodic maintenance
screen
[Input type] Parameter input
[Data type] Integer
[Unit of data] %
[Valid data range] 0 – 99
If, on the periodic maintenance screen, the remaining time reaches the
specified percentage of the lifetime, the item names and the remaining
time are displayed red to give a warning.