B-63330EN/03 4.DESCRIPTION OF PARAMETERS
- 175 -
2426 M code for counting up the number of parts
[Input type] Parameter input
[Data type] Integer
[Valid data range] 0 - 999999999
Specifies the M code for counting up the number of parts. To specify
no code, set 0. (Counting up is not performed with M00.) M98 and
M99 cannot be used for counting up. (If they are set, they are
ignored and counting up is not performed.)
2428 Number of decimal places of the 2nd auxiliary function (B)
[Input type] Parameter input
[Data type] Integer
[Valid data range] 0 - 8
Set the number of decimal places of the 2nd auxiliary function.
If 0 is set, the decimal point cannot be input.
2429 M code for tool replacement
[Input type] Parameter input
[Data type] Integer
[Valid data range] From 0 through 99999999 (excluding 01, 02, 30, 98, 99 and calling M
code)
Set the M code for a tool replacement command in tool life
management and in tool offset by the tool number. If 0 is set, is
regarded as 6 (M06) .
2431 M code to execute external device subprogram calls
[Input type] Setting input
[Data type] Integer
[Valid data range] 0 - 99999999
Set the M code to execute external device subprogram calls. When 0
is set, M198 is used. M01, M02, M30, M98, and M99 cannot be used
to execute external device subprogram calls. When a negative number,
1, 2, 30, 98, or 99 is set for this parameter, M198 is used to execute
external device subprogram calls.