4.DESCRIPTION OF PARAMETERS B-63330EN/03
- 144 -
2032 Allowable number of digits in a T code
[Input type] Parameter input
[Data type] Integer
[Valid data range] 1 - 10
Specify the allowable number of digits in a T code.
NOTE
To set the allowable number of digits in a T code
to 10, the use of a minus "-" in a T code must be
disabled.
2033 Allowable number of digits in a B code (2nd auxiliary function)
[Input type] Parameter input
[Data type] Integer
[Valid data range] 1 - 10
Specify the allowable number of digits in a 2nd auxiliary function.
When 0 is set, the allowable number of digits is assumed 3.
To enable the input of the decimal point, the number of decimal
places must be set for parameter No. 2428. In this case, the allowable
number of digits to be set for this parameter must include the number
of decimal places.
NOTE
To set the allowable number of digits in the 2nd
auxiliary function to 10, the use of a minus "-" in
the 2nd auxiliary function must be disabled.
2034 Type of auxiliary function to be used in binary input operation mode (remote
buffer)
[Input type] Parameter input
[Data type] Integer
[Valid data range] 0 - 3
Specify the type of auxiliary function to be used in binary input
operation mode.
0 : Second auxiliary function
1 : M function
2 : S function
3 : T function