A.PARAMETERS APPENDIX B-63874EN/05
- 744 -
A.1 REQUIRED PARAMETERS
A.1.1 Parameters Required for Basic Options
To use MANUAL GUIDE i, be sure to set the following parameters:
(1) No.8701#4 = 1
Read of “vacant” P code macro variables is enabled.
(In Series 30i, this parameter is not necessary.)
(2) No.3201#6 = 1
Program registration does not end with M end codes (M02, M30,
and M99).
(3) No.8650#0 = 1
When the reset key is pressed, C-EXE passes a key code to an
application program.
(4) No.8701#6 = 1
When the TV check is set to ON, edit operations are not regarded
as errors.
(In Series 30i, this parameter is not necessary.)
(5) No.3112#0 (SGD) = 0
This parameter enables or disables servo waveform display.
When this parameter is set to 1, other graphic functions become
unavailable.
(In Series 30i, this parameter is not necessary.)
(6) No.3103#3 = 1
In the FS160i and NC systems connected to a personal computer
(with an Ethernet board or HSSB board), NC software reads the
[HELP] key and changes screens even when a C-EXE screen is
being displayed.
To suppress this, set bit 3 of parameter No. 3103 to 1. The NC
software will then ignore any press of the [HELP] key while a
C-EXE screen is being displayed.
(In Series 30i, this parameter is not necessary.)
(7) No.9000#0 = 0
This parameter is for debugging machining macro program.
And if this parameter is set to 1, Manual Guide I does not work
correctly.
(8) No.3106#6 = 1
The function of C language executor refers to this parameter. If
this parameter is set to 1, Slant face machining does not work
correctly.
(The system checks this parameter in the case that
three-dimensional coordinate conversion is available.)
(9) No.8650#1 = 1
During display of the screen of C language executor, Alarm
screen is not changed when the alarm occurs.
(10) No.9000#7 = 0
If this bit is set, MANUAL GUIDE i does not update the screen
display at the time of operation, and cycle execution is not
performed normally.