B–63505EN/02
4.INTERFACE BETWEEN NC AND PMC
163
2 Trace memory contents display screen
PMC SIGNAL TRACE
TRCPRM
MONIT RUN
Trace
address and
mask data
(in parentheses)
1ST ADDRESS=X008(E1)
NO.
0000
0001
0002
0003
0004
0005
0006
0007
0008
76543210
........
I*******
II******
*I******
........
........
........
........
........
2ND ADDRESS=G000(FF)
76543210
........
********
********
********
........
........
........
........
........
STOP
10″LCD/14″CRT is displayed by 1 and 0.
Latest status
I mark : 1
* mark : 0
a. Soft key [TRCPRM]:Return to the trace parameter setting screen
(screen of previous page)
b. Soft key [EXEC]: Starts tracing.
Trace memory is cleared and each time a
specified signal changes, its status is recorded.
Trace memory is 256 bytes and if tracing is
executed 128 times by 2–byte tracing, tracing
is executed again from the head of memory.
c. Soft key [STOP]: Ends the tracing.
*The tracing parameters are held even if the power is turned off.
#7
K017
#6 #5 #4 #3 #2 #1 #0
#5 0 : Tracing starts by [EXEC].
1 : Tracing starts automatically after power on