APPENDIX
B–63505EN/02
E. MAINTENANCE OF OPEN CNC
(BOOT–UP AND IPL)
371
To open the status screen, double–click the icon in the system tray.
Alternatively, in the menu popped up by right–clicking, click OPEN.
Node: Node number
Name: Node name. (Define the node name in advance by using the
device manager in Windows 95/98 or the HSSB applet on the
control panel in Windows NT.)
Bus: Hardware communication status (0: Communication error, 1:
Communication established)
Status: Status (in hexadecimal)
Bit 1: Rotary switch position 1
Bit 2: End of boot processing
Bit 3: End of IPL processing
Bit 4: Rotary switch position 2
Bit 8: CNC system alarm
Pop up this window on communication error: By checking this item,
this screen is opened automatically when a communication error
occurs.
Clicking the [Close] button closes the screen.
Clicking the [Setting...] button opens the option setting screen.
Clicking the [About...] button opens the version information screen.
E.4.2
Status Screen