B–63505EN/02
1. DISPLAY AND OPERATION
31
Data displayed on the operation history screen
(1)MDI keys
Address and numeric keys are displayed after a single space.
Soft keys are displayed in square brackets ([ ]).
Other keys (RESET/INPUT, for example) are displayed in angle
brackets (< >).
A key pressed at power–on is displayed in reverse video.
1) Function key: <POS>, <PROG>, <OFFSET>, etc.
2) Address/numeric key: A to Z, 0 to 9, ; (EOB), +, –, (, etc.
3) Page/cursor key: <PAGE ↑>, <CUR ↓>, <CUR ←>
4) Soft key: [SF1], [SF2], etc.
5) Other key: <RESET>, <CAN>, etc.
6) Key pressed at power–on:
<RESET>
(2)Input and output signals
Indicates the bit.
General signals are displayed in the following format:
G 0 0 0 0 . 7 ↑
The ↑ mark indicates that the signal is
turned on.
The ↓ mark indicates that the signal is
turned off.
Indicates the address.
Some signals are indicated by their symbol names.
SBK ↑ (Indicates that the single block switch is turned on.)
Mode selection signals and rapid traverse override signals are displayed
as indicated below:
Input signal
MD1 ND2 MD4 REF DNC1
Name displayed
0 0 0 0 0 MDI
1 0 0 0 0 MEM
1 0 0 0 1 RMT
0 1 0 0 0 NOMODE
1 1 0 0 0 EDT
0 0 1 0 0 H/INC
1 0 1 0 0 JOG
1 0 1 1 0 REF
0 1 1 0 0 TJOG
1 1 1 0 0 THND
Input signal
ROV1 ROV2
Name displayed
0 0 R 100%
1 0 R 50%
0 1 R 25%
1 1 R F0%