B–63980EN/01
4. DESCRIPTION OF PARAMETERS
95
NOTE
When the set value is 0, the difference of radii is not checked.
3411 M code preventing buffering 1
3412 M code preventing buffering 2
3413 M code preventing buffering 3
LL
3420 M code preventing buffering 10
[Data type] Byte
[Valid data range] 0 to 255
Set M codes that prevent buffering the following blocks. If processing
directed by an M code must be performed by the machine without
buffering the following block, specify the M code.
M00, M01, M02, and M30 always prevent buffering even when they are
not specified in these parameters.
3421 Minimum value 1 of M code preventing buffering
3422 Maximum value 1 of M code preventing buffering
3423 Minimum value 2 of M code preventing buffering
3424 Maximum value 2 of M code preventing buffering
3425 Minimum value 3 of M code preventing buffering
3426 Maximum value 3 of M code preventing buffering
3427 Minimum value 4 of M code preventing buffering
3428 Maximum value 4 of M code preventing buffering
3429 Minimum value 5 of M code preventing buffering
3430 Maximum value 5 of M code preventing buffering
3431 Minimum value 6 of M code preventing buffering
3432 Maximum value 6 of M code preventing buffering
[Data type] Word
[Valid data range] 0 to 65535
When a specified M code is within the range specified with parameter
Nos. 3421 and 3422, 3423 and 3424, 3425 and 3426, 3427 and 3428, 3429
and 3430, or 3431 and 3432, buffering for the next block is not performed
until the execution of the block is completed.