4. DESCRIPTION OF PARAMETERS
B–63980EN/01
130
#7
7100
#6 #5 #4
HPF
#3
HCL
#2 #1
THD
#0
JHD
[Data type] Bit
JHD Manual handle feed in JOG feed mode or incremental feed in the manual
handle feed
0 : Invalid
1 : Valid
When JHD:=0 When JHD:=1
JOG feed
mode
Manual handle
feed mode
JOG feed
mode
Manual handle
feed mode
JOG feed f f
Manual handle feed f f f
Incremental feed f
THD Manual pulse generator in TEACH IN JOG mode
0 : Invalid
1 : Valid
HCL The clearing of handle interruption amount display by soft key [CAN]
operation is:
0 : Disabled.
1 : Enabled.
HPF When a manual handle feed exceeding the rapid traverse rate is issued,
0 : The rate is clamped at the rapid traverse rate, and the handle pulses
corresponding to the excess are ignored. (The graduations of the
manual pulse generator may not agree with the distance the machine
has traveled.)
1 : The rate is clamped at the rapid traverse rate, and the handle pulses
corresponding to the excess are not ignored, but stored in the CNC. (If
the rotation of the manual pulse generator is stopped, the machine
moves by the distance corresponding to the pulses preserved in the
CNC, then stops.)
#7
7102
#6 #5 #4 #3 #2 #1 #0
HNGx
[Data type] Bit axis
HNGx Axis movement direction for rotation direction of manual pulse generator
0 : Same in direction
1 : Reverse in direction
4.27
PARAMETERS OF
MANUAL HANDLE
FEED AND HANDLE
INTERRUPTION