B–63980EN/01
4. DESCRIPTION OF PARAMETERS
191
#7 #6 #5 #4 #3 #2 #1 #0
16500 YSF SAT SF0
[Data type] Bit
SF0 The safety zone of type:
0: A is used.
1: B is used.
NOTE
When type B is used, punching is inhibited in punching
mode and entry is inhibited in laser mode.
SAT When punching is inhibited in the safety zone, the block in which a T
command is specified is checked:
0: In advance.
1: After the FIN signal to complete the T command has been received.
YSF When a safety zone check is executed, the inhibited area along the Y axis
extends from the values set in parameters 16507, 16510, 16513, and
16516:
0: In the negative direction.
1: In the positive direction.
#7 #6 #5 #4 #3 #2 #1 #0
16501 SZ4 SZ3 SZ2 SZ1
[Data type] Bit
SZj When a safety zone check is executed, in the #j (j=1 to 4) area,
0: An entry is inhibited.
1: Punching is inhibited.
#7 #6 #5 #4 #3 #2 #1 #0
16502 SOF ACZ ZNO SZ1 GSZ ZIO SZC MDP
[Data type] Bit
MDP On the safety zone setting display,
0: The workpiece coordinate system is indicated.
1: The machine coordinate system is indicated.
SZC On the safety zone setting display, the data for:
0: Any zone can be changed.
1: Those zones to be set automatically (parameter 16534) can be
changed.
ZIO When the safety zone is automatically set by an external signal, the
position of a workpiece holder is detected according to:
0: The on and off states of the SAFZ signal used to detect the position of
a workpiece holder.
1: The on state of the SAFZ signal used to detect the position of a
workpiece holder.
4.41
PARAMETERS FOR
THE SAFETY ZONE