B–63980EN/01
4. DESCRIPTION OF PARAMETERS
59
1876 One–pitch interval of the inductosyn
NOTE
When this parameter has been set, the power must be
turned off before operation is continued.
[Data type] Word axis
[Unit of data] Detection unit
[Valid data range] 1 to 32767
Set a one–pitch interval of the inductosyn for each axis.
SUPPLEMENTAL REMARK
To use an absolute–position detector using Inductosyn, set
the following digital servo parameters as well:
Bit 4 (INDx) of parameter No. 2015
The absolute–position detect function by
Inductosyn is:
0 : Disabled.
1 : Enabled.
Parameter No. 2141 Inductosyn data acquisition time
Set a time requirement for acquiring the
Inductosyn data. If the setting is 0, 20 ms is
assumed. (For the setting, contact the scale
manufacturer.)
#7
1902
#6 #5 #4 #3 #2 #1
ASE
#0
FMD
NOTE
After this parameter has been set, the power must be turned
off then back on for the setting to become effective.
[Data type] Bit
FMD The FSSB setting mode is:
0 : Automatic setting mode.
(When information including an axis–amplifier relationship is set on
the FSSB setting screen, parameter Nos. 1023, 1905, 1910 through
1919, 1936, and 1937 are set automatically.)
1 : Manual setting 2 mode.
(Set parameter Nos. 1023, 1905, 1910 through 1919, 1936, and 1937
manually.)
ASE When automatic setting mode is selected for FSSB setting (when the FMD
parameter (bit 0 of parameter No.1902) is set to 0), automatic setting is:
0 : Not completed.
1 : Completed.
(This bit is automatically set to 1 upon the completion of automatic
setting.)