4. DIAGNOSTIC FUNCTION
B–61863E–1/06
PMC CONTROL SOFTWARE
130
When the USRDGN key on the diagnosis screen (PMCDGN) of the PMC
screen is pressed, the execution status of each user task (including the
third-level ladder program) is indicated dynamically (Fig. 4.4).
With this function, the status of the application program can be
determined. When the user task execution status is being indicated, the
application display task is ignored.
PMC MONIT USER TASK #1 MONIT RUN
ID NAME LV STATUS WAIT-INF WAIT-ID
LAD3 10 READY
10 TASK__O1@ 10 ACTIVE
11 TASK__O2# 11 READY
12 TASK__O3 12 WAIT TIM
13 TASK__O4 13 WAIT EVT.O 1
14 TASK__O5 14 WAIT EVT.A 3
15 TASK__O6 15 WAIT PKT 2340
16 TASK__O7 STOP
17 TASK8 17 READY
>
[ ] [ ] [ ] [ ] [ ]
Fig.4.4 User Task Execution Status Display Screen
[Display items]
ID NAME LV
STATUS
WAIT-INF WAIT-ID
11 TASK1 # 13 WAIT EVT.O 10
ID for wait information
Task IDD
Task name
Device
Task level
Execution status
Wait information
(1) Device information
Message Description
#
@
RS-232C being used
NC command editing in progress
(2) Execution status
Message Description
ACTIVE
READY
WAIT
STOP
ERROR
Active status
Ready status
Wait status
The task is in stopped status.
The task was deleted by the system because it called a
library not supported.
4.4
USER TASK
EXECUTION STATUS
DISPLAY