11. NC WINDOW LIBRARY
B–61863E–1/06
PMC LIBRARY
282
With SC/SC3/SC4, 16i/18i/21i
–
10 : Reject (low-speed) type window library processing command which was
specified last, has not been completed)
–1: Reject (because other processing is being executed at the NC side,
the processing command has been ignored)
0: Normal termination
1: The specified function code is incorrect.
2: The specified data length is incorrect.
3: The specified data number is incorrect.
5: The specified data is incorrect.
6: The required option is not provided.
7: Write-protect is in effect.
With PMC-NB/NB2, 15i–A
–10: Reject (The low-speed window library processing last specified has
not been completed.)
0: Normal termination
1: The specified function number was not found.
2: A setting error occurred. For example, the corresponding NC
function is not provided.
3: The specified axis is not provided.
11.4
COMPLETION CODE
TYPES