12. NC COMMAND PROGRAM (PMC-SC)
B–61863E–1/06
PMC LIBRARY
324
[Returns]
ret Complete code : –11, –2, –1, 0, 1, or 2
–11: Preparation to input the NC program number list in the NC is
not completed or has not been executed.
–2: The NC entered the reset status.
–1: The request to read the program number list was rejected.
When an attempt is made to execute this command, this
completion code is returned while background editing is being
performed on the NC, during downloading, or when the NC is
in the alarm status.
0: Reading of the program number list in the NC has terminated
normally.
1: A value other than 1 or 2 was set to specify the tool post.
2: The data length is incorrect. The specified value is less than 5.
[Remarks]
______