1. SCREEN INDICATIONS AND OPERATIONS
B–63785EN/01
88
As shown in the following example, the image on each page is output as
is. When all data output is specified, the system log (new) is output first,
followed by the system log (old).
%
============================== SYSTEM ALARM FILE ==============================
FANUC SERIES 15I F000B
SYS_ALM 400 BUS ERROR
CPU CARD(MAIN)
ERROR OCCURRED AT 1998/10/16 14:13:52
PROGRAM COUNTER : 021E6860H
ACT TASK : 0000000CH
ACCESS ADDRESS : 78000020H
ACCESS DATA : –
ACCESS OPERATION : READ FROM CPU CARD(MAIN)
+–––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––+
| The system alarm had been occurred, the system was stopped. |
+–––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––+
===============================================================================
SOFTWARE INFORMATION 1
CONTROL REGISTERS
8090C000 00002000 021E6860 0008B930 22000000 20000000 021E745C 02156BF4
00071201 78000007 40000000 78000000 800003A0 026F01C0 026FFE00 00000000
00000000 780001AA 820280D0 00000000 00000000 00000000 00000000 00000000
GENERAL PURPOSE REGISTERS
021E6C84 025BA988 00000000 025BAA88 0251D580 00000004 025BA7E6 00000000
00400000 78000020 00000000 00000008 00000002 00000000 00000000 00000000
00000000 00000000 00000000 00000006 00000000 021E7444 021E745C 021E7448
00001889 00000002 00000000 025BAA23 0240FE9C 00000000 00000000 021E745C
FLOATING POINT REGISTERS
00000002 FFF80000 00000000 00000000 00000000 00000000 00000000 00000000
00000000 00000000 00000000 00000000 00000000 00000000 00000000 00000000
00000000 00000000 00000000 00000000 80000000 43300000 00000000 40600000
00000000 43300000 00000000 40000000 00000000 00000000 00000000 00000000
00000000 00000000 00000000 00000000 00000000 00000000 00000000 00000000
00000000 00000000 00000000 00000000 00000000 00000000 00000000 00000000
00000000 00000000 00000000 00000000 00000000 00000000 00000000 00000000
00000000 00000000 00000000 00000000 00000000 00000000 00000000 00000000
===============================================================================
SOFTWARE INFORMATION 2
ACT TASK : 0000000CH
STACK ADDRESS : 025BA9D0H
STACK DATA
025BABEC 00000000 02156E28 02156B04 02156E28 025A2A60 025A2A24 0216D364
025BABCC 00000005 00000001 00000000 00000000 00000000 00000000 00000000
00000000 02177E48 025BABAC 02408534 02411690 02411690 00000000 00000000
00000000 02178024 025BAB84 00000004 0240FE9C 02411690 02408534 025330C0
00000004 0217807C 025BAB64 00000004 00000004 02408534 0240FE9C 025330C0
.
.
.
===============================================================================
================================= END OF DATA =================================
%
#7
0013
#6
DSL
#5 #4 #3 #2 #1 #0
[Input classification] Setting input
[Data type] Bit
Bit 6 DSL The system log screen is:
0: Not displayed.
1: Displayed.
Output format
1.12.3
Parameter