1. SCREEN INDICATIONS AND OPERATIONS
B–63785EN/01
22
3521 Pulse coder temperature information
[Data type] Integer axis
[Unit of data] °C
Displays the temperature of the printed circuit board in the αi pulse coder.
When the temperature reaches 100°C (the ambient temperature in the
pulse coder is about 85°C), a motor overheat alarm is issued.
NOTE
The temperature at which an overheat alarm is issued may
have an error of up to 5°C.
3530 Three–dimensional error compensation amount
[Data type] Integer axis type
[Unit of data] Detection unit
3540 OVC level
[Data type] %
[Meaning] The ratio of the soft thermal (OVC) level to the alarm generation level is
indicated.
3700
Shift between the motor absolute position and the offset data in the abso-
lute–position detection function with the Inductosyn method
[Data type] Integer axis type
[Unit of data] Detection unit
The remainder of (motor absolute position – offset data)/(one–pitch
interval) is indicated.
3701
Offset data from the Inductosyn in the absolute–position detection function
with the Inductosyn method
[Data type] Integer axis type
[Unit of data] Detection unit
The offset data which the CNC received at machine–position calculation
is indicated.
D Three–dimensional error
compensation
D OVC level
D Absolute–position
detection in Inductosyn
method