2. 15i SERIES HARDWARE
B–63785EN/01
138
With the rotary switch SW1 on the board and the setting pin SW5 on the
CNC display unit with PC functions, the starting sequence at power–up
can be changed.
Rotary
switch SW1
setting
Setting pin
SW5
setting
Description
0 Open Setting for maintenance purposes
The start menu is displayed, and booting or IPL can be
performed from the CNC display unit with PC functions.
1 Open Setting for normal operation
The start menu is not displayed.
Booting or IPL cannot be performed from the CNC dis-
play unit with PC functions.
2 Shorted The CNC and the CNC display unit with PC functions
will be started independently of each other without
handshaking.
– CNC
– Even if the CNC display unit with PC functions is
not connected or turned on, it is possible to start
the CNC only and operate it. (Its operation
requires a display dedicated to the CNC, an MDI,
an operator panel, and others.)
– Even if the CNC display unit with PC functions is
connected and turned on, the start menu is not
displayed.
– CNC display unit with PC functions
– Even if the CNC is not connected or turned on, it is
possible to start the CNC display unit with PC func-
tions only and operate it.
– The temperature control function of the CNC dis-
play unit with PC functions does not operate.
Make sure that the CNC display unit with PC func-
tions is in the recommended operating temperature
range before using it.
– Even if the CNC is connected and turned on, the
start menu is not displayed. It is not possible to
perform boot and IPL operations from the CNC
display unit with PC functions.
During normal operation, this setting is disabled. Use
this setting during maintenance only.
NOTE
For the location of the setting pin SW5 of CNC display unit
with PC functions, see the Section 2.15.2.
D Setting adjustments
Rotary switch SW1
(for connecting an CNC
display unit with PC
functions)