6. AC SPINDLES
B–63785EN/01
360
Conversion from the specified spindle speed (or S code), which is a
command for specifying the rotation speed of the spindle, to the spindle
motor command voltage signal, which is an actual command for
specifying the rotation speed of the motor, is performed totally in the
PMC. The CNC controls the specified voltage using the spindle motor
command voltage signal regardless of the specified spindle speed (or S
code).
The PMC performs conversion by taking the following into account:
(1) Spindle maximum/minimum rotation speed clamp
(2) Gear selection
(3) Spindle override
(4) Special control modes such as constant surface speed control
(5) Spindle normal/reverse rotation and stop commands
(6) Spindle orientation and other special commands
For the analog spindle, it is necessary to adjust the offset voltage and gain
of the D/A converter.
(1) D/A converter offset adjustment
Offset voltage adjustment is needed if the spindle creeps (rotates at a
low speed) even when the specified spindle speed is 0 min
–1
.
A symptom listed below may occur if the offset voltage is poorly
adjusted.
1) Specifying 0 rpm as the spindle speed cannot keep the spindle from
creeping.
2) Specifying a very slow speed causes the spindle to rotate in the
reverse direction.
3) There is a mismatch between the specified spindle speed and actual
spindle speed; the amount of speed mismatch does not change
regardless of whether the specified speed is low or high.
[Adjustment procedure] Follow the steps below.
1) Reset parameter number 5613 to 0 (standard value).
2) Specify the spindle speed that corresponds to a spindle speed
analog output of 0.
3) Measure the output voltage.
4) Set the parameter (No. 5613) to the following value:
Value +
* 8191 Voltage measurement (V)
12.5
5) Specify the spindle speed that corresponds to a spindle speed
analog output of 0 again, and make sure that the output voltage is
0 V.
(2) D/A converter gain adjustment
Before gain adjustment, offset voltage adjustment should be
completed. Gain adjustment must be performed if there is a mismatch
between the specified spindle speed and actual spindle speed. If this
adjustment has not been performed correctly, the following symptom
occurs.
6.2.2
S Analog Voltage
(D/A Converter)
Adjustments