B–63785EN/01
1. SCREEN INDICATIONS AND OPERATIONS
43
4732 Memory address specification 1
[Input type] Parameter input
[Data type] Integer
[Valid data range] 0 – 999999999
In trace data 1 of waveform diagnosis function, the memory address for
the tracing of specified memory is specified.
NOTE
Specify an existing address.
If an illegal address is specified, a system alarm may be
issued.
4733 Target board specification 2
[Input type] Parameter input
[Data type] Integer
[Valid data range] 0 – 1
In trace data 2 of waveform diagnosis function, the target board for the
tracing of specified memory is specified.
0: CNC main board
1: Customer’s board
4734 Access size specification 2
[Input type] Parameter input
[Data type] Integer
[Valid data range] 0 – 4
In trace data 2 of waveform diagnosis function, the access size for the
tracing of specified memory is specified.
0: One byte (signed)
1: One byte (unsigned)
2: Two bytes (signed)
3: Two bytes (unsigned)
4: Four bytes (signed)
NOTE
If an illegal access size is specified, a system alarm may be
issued.