1. SCREEN INDICATIONS AND OPERATIONS
B–63785EN/01
34
Data tracing starts.
(1) Display the waveform–diagnosis graphic screen.
(2) Press the [TRACE] soft key.
At the top of the screen, “Tracing” is indicated. When tracing ends,
“Tracing” is deleted.
Tracing continues even if the screen is changed during tracing.
NOTE
In the type–1 tracing condition, waveform drawing starts
immediately after the [TRACE] soft key is pressed.
In the type–2 tracing condition, waveform drawing starts
immediately after the specified trigger event occurs.
In the type–3 tracing condition, waveform drawing starts
immediately after the delay period elapses after the
specified trigger event occurs.
Tracing or waveform drawing is stopped.
(1) Display the waveform–diagnosis graphic screen.
(2) Press the [STOP] soft key.
If tracing is being performed, it is stopped. If a waveform is being drawn,
drawing is stopped.
The traced data is deleted and drawing is cleared.
(1) Display the waveform–diagnosis graphic screen.
(2) Press the [ERASE] soft key.
Traced data cannot be deleted during tracing. When tracing starts, the
preceding data is automatically deleted.
On the waveform–diagnosis graphic screen, soft–key operations allow a
waveform to be moved and to be enlarged/reduced in the horizontal and
vertical directions.
These operations can be performed during tracing.
Press the [WAVE1 ° ], [WAVE1 ±], [WAVE2 °], [WAVE2 ±],
[WAVE3 °], [WAVE3 ±], [WAVE4 °], and [WAVE4 ±] soft keys to move
the corresponding waveforms up and down.
Press the [TIME ³] and [TIME ²] soft keys to move the entire
waveforms right and left.
Tracing data
D Starting tracing
D Stopping tracing/drawing
D Deleting waveform
Waveform
movement/enlargement/r
eduction
D Moving waveform