B–63785EN/01
2. 15i SERIES HARDWARE
135
If an error occurs, the LEDs repeatedly flash ”LONG” then ”SHORT.”
(For ”LONG,” the LED lights for a long time. For ”SHORT,” the LED
lights for a short time.)
STATUS LED
indication
No.
LONG
1 2 3 4
SHORT
1 2 3 4
Fast Ethernet/Fast data server state
1 f F
f F
F f
F f
Failure caused by
Fast data server
SDRAM paruty alarm
2 f F
F f
f f
f f
General invalid instruction
3 f F
F f
F f
f f
Invalid slot instruction
4 f F
f F
F f
f f
Failure caused by
another board
NMI of another module
NOTE
If an error, indicated by repeatedly flashing a LONG and
SHORT combination other than the above, occurs, contact
FANUC.
No.
LED indication
1 2 3
Data server board state
1 j J J A bus error occurred on the Fast data server.
2 j J J Parity error occurred in memory.
Communication status (LEDs L5 through L8)
No. LED indication Communication status
1 F Z
Z Z
Lights when a connection is made with 100BASE–TX.
2 Z Z
F Z
Lights when data is received.
3 Z Z
Z F
Lights when data is received.
4 Z F
Z Z
Lights when the Fast data server is successfully con-
nected to the hub.
Communication status (COL LED)
No. LED indication Communication status
1 F Lights if a data collision occurs.
COL: This LED lights frequently if there is excessive traffic on the
communication line or if there is excessive peripheral electrical
noise.
D STATUS LED indications
if an error occurs (LEDs
L1 through L4)
D ALARM LED indications
if an error occurs
D LED indications related
to communication status