5. DIGITAL SERVO
B–63785EN/01
314
This section explains how to initialize digital servo parameters just after
the machine tool is installed.
1. Make sure that the machine is at an emergency stop, then switch on the
power.
2. Set up the parameter needed to display the servo setting screen. When
the parameter is 0, the screen can be displayed. So, it is unnecessary
to change the parameter from the initial state.
#7
0015
#6 #5 #4 #3 #2 #1 #0
SVS
#0 (SVS) 0: Displays the servo adjustment screens.
1: Does not display the servo adjustment screens.
3. Switch the power off and on again.
4. Displays the servo parameter setting screen according to the procedure
in II 2.5 of the applicable operator’s manual (B–63324EN–1).
5. Enter the data necessary for parameter initialization, using the cursor
and page keys.
PRM 1804
PRM 1874
PRM 1806
PRM 1820
PRM 1977
PRM 1978
PRM 1879
PRM 1876
PRM 1891
PRM 1896
(1) INIT. BIT
#7
1804
#6 #5 #4 #3 #2 #1
DGPRM
#0
PLC01
#1 (DGPRM)l 0: Initializes the digital servo parameters.
1: Does not initialize the digital servo parameters.
#0 (PLC01) 0 Specifies use of the current values in PRM 1876 and 1891 without
modifying them.
1: Specifies use of the current values in PRM 1876 and 1891 multiplied
by 10.
5.1
SERVO PARAMETER
INITIALIZATION
PROCEDURE