B–63785EN/01
2. 15i SERIES HARDWARE
195
Name Meaning Settings
SW5
TM7
(A20B–
2100–
0780 to
–0785)
Reserved Default on
manufacture.
Never
change.
TM7
SW5
: Short for the
PANEL i
Open for the CNC
display unit with PC
functions
TM10 Reserved Test usage.
Never
remove.
TM10
: Short
GR4 (Green)
COP7
GR1 (Green)
RE1 (Red)
CD34 (FDD Signal)
CNH3 (HDD Signal)
+5V (Green)
HDD (Green)
CNC (Green)
CRD (Green)
BUS (Green)
BAT (Red)
FAN (Red)
TRM (Red)
Or
*6
GR2 (Green)
GR3 (Green)
RE2 (Red)
RE3 (Red)
RE4 (Red)
Name1
*6
Name2
*6
Color
Status
GR1 +5V GREEN Power is turned on (+5V).
GR2 HDD GREEN HDD access LED.
GR3 CNC GREEN CNC status is normal.
GR4 CRD GREEN PCMCIA access LED.
RE1 BUS RED HSSB is not ready. The cause is as follows.
– CNC power is not turned on.
– Optical fiber cable is not connected or cable is broken.
– Something goes wrong with the interface board for CNC.
– Something goes wrong with the CNC display unit with PC functions or PANEL i.
RE2 BAT RED Battery alarm. The battery on CNC display unit with PC functions or PANEL i is exhausted.
Please exchange it.
RE3 FAN RED FAN for basic unit or FAN for HDD is stopped. Please exchange either FAN.
RE4 TRM RED
Thermal alarm. The CPU detected high temperature outside the use range.
The speed of the CPU decreases.
*6: Printed name is different by the revision of the main board.
2.15.2.2
Adjustment
2.15.2.3
LED display