2. 15i SERIES HARDWARE
B–63785EN/01
128
(1) LED display upon the occurrence of an alarm condition (STATUS and
BUSDRY: red)
J On l Blink
No. LED display LCD status
1 STSATUS J The display interface cable is broken.
2 BUSRDY J The display interface cable is broken, or the LCD unit has
detected a failure.
l At power–on, the breaking of cable is detected.
(1)
Graphic card
LCD control printed circuit board
Connector
No. Name Specification Function Remarks
(1) Graphic card A20B–3900–0150 Graphic display Color
Setting the rotary switch
The rotary switch is factory–set to 0 by FANUC.
Adjust the rotary switch setting as listed below, depending on the
connection of the unit.
LCD unit Rotary switch setting
Using the unit as the second LCD unit 0 to 3
Using the unit as the first LCD unit 8 to F
Connecting and using just the single LCD unit
(in the maintenance mode)
4 to 7
D LED display
D Card mounting locations
D Setting adjustments