B–63785EN/01
7.TROUBLESHOOTING
393
A communication error occurred between the CNC and a serial spindle
or between serial spindles.
Check the following:
(1)Is the serial spindle amplifier powered?
(2)Is the cable to the serial spindle attached to the correct connector?
(3)Is the cable to the serial spindle broken?
(4)Is there any source of noise near the system?
(5)Is the ground terminal of the CNC disconnected?
(6)Is the ground terminal of the spindle amplifier disconnected?
If the above checks do not reveal any abnormality, the printed circuit
board in the CNC or the spindle amplifier may be defective.
The motor number assigned to a spindle is illegal.
A value beyond the allowable range is set in parameter No. 5841. Check
the parameter setting.
7.10.5
Alarm SP0225
(Serial Spindle CRC
Error)
Alarm SP0226
(Serial Spindle Framing
Error)
Alarm SP0227
(Serial Spindle
Reception Error)
Alarm SP0228
(Serial Spindle
Communication Error)
Alarm SP0229
(Communication Error
between Serial Spindle
and Spindle Amplifier)
Cause and action
7.10.6
Alarm SP0230
(Spindle Motor Number
Outside Allowable
Range)
Cause and action